44
Pressure - Temperature Table
Bar °C °F
0.50 110.5 230.9
0.55 111.5 232.7
0.60 112.5 234.5
0.65 113.5 236.3
0.70 114 237.2
0.75 115 239
0.80 115.5 239.9
0.85 116.5 241.7
0.90 117.5 243.5
0.95 118 244.4
- Press key to conrm group active or non active.
- Press
key to return to the previous page without conrming.
Note: When DELIVERY IN WASH mode is activated for groups, press
to escape wash menu
into standby mode and use other groups as normal while wash cycle is delivered.
12. Setpoint Temperature (Steam)
The setpoint temperature allows you to choose the pressure/temperature of the steam boiler when
machine is switched on and in standby ready for use.
- Press
to activate menu, screen will display SETPOINT PRESS XX.XX BAR.
- Use
or keys to adjust the working pressure/steam point.
- Press
key to conrm and pass to the next step.
- Press
key to return to the previous page without conrming.
6.0 PROGRAMMING AND SET UP
Bar °C °F
1.00 119 246.2
1.05 119.5 247.1
1.10 120.5 248.9
1.15 121 249.8
1.20 122 251.6
1.25 112.5 252.5
1.30 123 253.4
1.35 124 255.2
1.40 124.5 256.1
1.45 125 257
1.50 126 258.8