15. MAX
®
4000 SPECIFICATIONS
FEATURE
SPECIFICATION
Size
9.5” height x 11.5” width x 19.5” depth
240 mm height x 300 mm width x 495 mm depth
Weight
32 lbs. (14.5 kg)
Power Requirements
100-120 VAC, 50/60 Hz @ 8A, 0.2A Heat Off
220-240 VAC, 50/60 Hz @ 4A, 0.1A Heat Off
Operating
Environment
0-40 ºC @ 50% humidity; 0-30 ºC @ 80% humidity
Non-condensing, non-explosive
Heating Range
25 °C to 225 °C on the MAX
®
4000
25 °C to 275 °C on the MAX
®
4000XL
Sample size
100mg to 40g (0.2 ± 0.1g to 39.9 ± 0.1g)
Balance Resolution
MAX
®
4000: 0.001g
MAX
®
4000XL: 0.0001g
Moisture Resolution
MAX
®
4000: 0.01% Moisture (fixed at two decimal digits)
MAX
®
4000XL: 0.001% Moisture (Default) or programmable from
0.0 to 0.00000
Repeatability
0.002% standard deviation depending upon Test Program.
Moisture Range
MAX
®
4000: 0.1% to 99.9% Moisture
MAX
®
4000XL: 0.005% to 100% Moisture
Dry Weight Range
0% to 300%
Heater Calibration
(MAX
®
4000XL only)
Menu driven.
NIST Traceable using an accessory Temperature Calibration Kit
with a 1.5 °C precision.
Calibration points every 25 °C from 50 °C to 275 °C.
Verification points at every calibration point or up to four
user-programmable verification points.
Programmable calibration reminder.
Temperature Control
±1 °C of setpoint
Test Temperatures
User programmable idle temperature, test temperature, high start
temperature, and temperature ramp rate.
Multiple test temperatures are programmable through linked test
sequences. (MAX
®
4000XL only)
Test Display
Moisture, solids, or dry weight
Custom result calculations and optional secondary custom result
calculation in addition to primary calculation. (MAX
®
4000XL only)
Current and programmed chamber temperature.
Elapsed test time.
Sample name.
Rate of weight loss.
Linked test results for multistage test. (MAX
®
4000XL only)
Ending Criteria
MAX
®
4000: Prediction, Rate
Rate can be set as low as 0.01%/minute
MAX
®
4000XL: Prediction, Rate, Time, Time or Rate,
TempPredict, TempRate, TempTime or Rate
Rate can be set as low as 0.0010%/minute
Parameter Expert
(MAX
®
4000XL only)
Assists user to develop Test Program parameters to match a
reference method.

Table of Contents

Other manuals for Arizona Instrument COMPUTRAC MAX 4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Arizona Instrument COMPUTRAC MAX 4000 and is the answer not in the manual?

Arizona Instrument COMPUTRAC MAX 4000 Specifications

General IconGeneral
BrandArizona Instrument
ModelCOMPUTRAC MAX 4000
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals