7-30 CHP Max™ Headend Optics Platform Chassis, Controllers and Power Supplies Rev D
3. At the command prompt, type commit.
4. At the command prompt, type reboot.
5. Wait for the SMM-2 to initialize.
SMM-2 Serial Mode Connection
1. From a laptop computer USB port, connect a standard USB 2.0 A Male to Mini-B 5-pin
Male cable of any length to the SMM-2, as shown in Figure 7.5.
2. Start a terminal program, such as PuTTY (refer to Figure 5.26).
Figure 7.26
PuTTY Configuration
Window
3. Click on the Serial button.
4. Determine the Serial line field COM port number from the Control Panel>Device
Manager>Ports (COM & LPT)>Gadget Serial (COM#) and modify if necessary to match
(refer to Figure 5.27).
Note To change the USB connection mode to Ethernet, replace "serial" with
"ethernet" in step 2 and proceed with the remaining steps listed above.
Note The COM port number may change if the USB cable is moved to a different
USB port on the laptop computer.