Mechanical & Environmental specification:
I.
Design Flush mounting case
II.
Weight 2.50 Kg approximate
III.
Pollution Degree II
Drawing References
Drawing
References
: For Cabinet Type without IP cover MAC01974
: For Cabinet Type with IP cover MAC01975
: For Electrical and Back Terminal Connections APR07409
1.5 Typical Tests Information
Electromagnetic Compatibility Type Test:
Sr. No.
Standard Test
I.
High Frequency
Disturbance Test
IEC60255-22-1,
IEC60255-26
(ed3): 2013
1) 2.5 kV Common Mode
2) 1 kV Differential Mode
EUT Condition Energized
II.
Electrostatic
Discharge Test-
Direct Application
IEC60255-22-2,
IEC60255-26
(ed3) : 2013
1) 8kV air discharge
2) 6kV contact discharge
Test Mode Direct and Indirect Method
EUT Condition Energized
III.
Fast Transient
Disturbance Test
IEC60255-22-4,
IEC60255-26
(ed3) : 2013
Test Voltage : ±4 KV
Repetition rate : 5 KHz and 100 KHz.
EUT Condition : Energized
IV.
Surge Immunity
Test
IEC60255-22-5,
IEC60255-26
(ed3) : 2013
Front time / time to half value : 1.2/50 µS
Source impedance : 2
Common Mode : ±4 KV
Differential Mode : ±2 KV
EUT Condition : Energized
V.
Pulse Magnetic
Field Immunity
Test
IEC61000-4-9,
IEC60255-26
(ed3) : 2013
Class 5: 1000A/m field applied continuously in all
planes for the EUT
VI.
Radiated
Electromagnetic
Field Disturbance
Test
IEC60255-22-3,
IEC60255-26
(ed3) : 2013
Voltage Level
Frequency Range
Modulation
Spot Frequency
10 V/m
80 - 1000 MHz
80% AM @ 1 KHz
80, 160, 380, 450 & 900
MHz