7. Connect the dual power supply wiring to the rear panel connectors.
8. Power the unit on from the equipment rack.
9. The installation is now complete and ready for system commissioning.
Notes:
1) Ensure power supply cabling is adequately rated.
2) Always route power supply cabling away from input
cabling in the equipment rack to reduce the risk of
noise pick-up.
IN
+-
18-40V 2A
18-40V
2A
1
2
CONTACTS OUT
1 - 6
7 - 12
CONTACTS OUT
SUPPLY: 18-40 V DC
Use one of the two methods shown in the diagram below to
terminate the cabling in the Wago connectors.
When the screwdriver is removed, the bare end of the wire
will be held securely by the contact spring.
To remove the wire, reverse the process.