Manual, F/T Sensor, Ethernet Axia
Document #9610-05-Ethernet Axia-09
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel:+1 919.772.0115 • Fax:+1 919.772.8259 • www.ati-ia.com
48
The descriptions for the elds on the ADC Settings page, Figure 6.5, are the following:
Active Calibration: A user may select one of two calibrations to be applied to the force and torque
readings. For more information about the two calibration options, refer to
Section 15.3—Calibration Ranges.
ADC Sampling The user may select the sampling frequency for low-pass ltering.
Frequency: For more information about the sampling rate options, refer to
Section 4.3—Sample Rate)
Low-Pass Filter Cutoff The user may select a value for the cutoff frequency for low-pass ltering. The No
Frequency: Filter value disables the low-pass ltering feature. For more information about the
ltering values, refer to Section 4.5—Low-Pass Filter.
Software Bias Values: The user may enter values for the bias offset applied to the sensor strain gage
readings. To remove the bias offset, set the elds to all zeros.
Note that the strain gage readings do not have a 1:1 correspondence to force and
torque readings.
6.5 Thresholding Page (moncon.htm)
On the Thresholding page, the user can set up to 16 threshold conditions. Threshold conditions compare
the sensor readings to simple user-dened threshold statements. After the user enables threshold monitoring
and a sample is read, the user-dened output code for all threshold conditions satised by that sample are
compared with a bitwise OR function or AND function (as dened by the user) to form the threshold output.
In practice, it is very unlikely that more than one threshold sample is satised in a single sample. If the
threshold conditions are exceeded, the threshold monitoring latch is set, and threshold monitoring is paused
until the user issues a reset command or the user dened momentary time delay has passed.
Each threshold condition can be congured for:
• the axis to monitor
• the type of comparison to perform
• the threshold value to use for the comparison
• the output code to send when the comparison is true

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ATI Technologies Axia80-M8 and is the answer not in the manual?

ATI Technologies Axia80-M8 Specifications

General IconGeneral
BrandATI Technologies
ModelAxia80-M8
CategoryAccessories
LanguageEnglish

Related product manuals