Type V Hz Approval I
tot
P
(1)
I
tot
FF
(1)
Recommended
wire section (2)
Recommended
wire section (3)
Main
fuses P
(A) (4)
Main
fuses
FF (A)
(4)
GA 22 575 60 cULus /
cCSAus
35.9 39.9 AWG8 AWG6 50 60
GA 26 230 50 IEC 99.3 109.3 70 mm² / 35
mm²
95 mm² / 50
mm²
160 160
GA 26 230 60 IEC 99.9 109.9 70 mm² / 35
mm²
95 mm² / 50
mm²
160 160
GA 26 380 60 IEC 50.2 56.2 35 mm² / 16
mm²
35 mm² / 25
mm²
125 125
GA 26 400 50 IEC 57 62.7 25 mm² / 16
mm²
35 mm² / 16
mm²
80 80
GA 26 460 60 IEC 50.1 55.1 25 mm² / 16
mm²
25 mm² / 16
mm²
80 80
GA 26 200 60 cULus /
cCSAus
111.8 123.3 AWG1/0 AWG2/0 150 175
GA 26 230 60 cULus /
cCSAus
99.6 109.6 AWG1/0 AWG2/0 150 175
GA 26 460 60 cULus /
cCSAus
50 55 AWG4 AWG4 80 80
GA 26 575 60 cULus /
cCSAus
41.9 45.9 AWG6 AWG6 60 60
Remarks :
(1): current in the supply lines at maximum load and nominal voltage
(2): suggested wire section under worst case conditions (Pack)
(3): suggested wire section under worst case conditions (Full-Feature)
(4): Maximum fuse value
Fuse specifications IEC: aM
Fuse specifications UL/cUL: HRC Form II - UL: Class RK5
14.3 Motor overload relay settings
Type V Hz Approval Setting F21 (A) Setting Q15 (A)
GA 15 230 50 IEC 36 0.7
GA 15 230 60 IEC 36.6 0.7
GA 15 380 60 IEC 25.9 0.4
GA 15 400 50 IEC 20.6 0.4
GA 15 460 60 IEC 18.3 0.4
GA 15 200 60 cULus / cCSAus 41.2 0.7
GA 15 230 60 cULus / cCSAus 36.6 0.7
GA 15 460 60 cULus / cCSAus 18.3 0.5