In the example shown, the screen shows the unit used (hrs) and the value (5000): the regulator module has
been in service during 5000 hours.
7.14 Calling up loading hours
Starting from the Main screen:
Press Scroll button (12) until <d.4> is shown and then press Enter button (13):
The screen shows the unit used <hrs> (or <x1000 hrs>) and the value <1755>: the compressor has been
running loaded during 1755 hours.
7.15 Calling up load relay
Starting from the Main screen:
Press Scroll button (12) until <d.5> is shown and then press Enter button (13):
This screen shows the number of unload to load actions (x 1 or - if <x1000> lights up - x 1000). In the
above example, the number of unload to load actions is 10100.