10.4 Stopping
Elektronikon regulator
Control panel Elektronikon®
Control panel Elektronikon® Graphic
Procedure
Step Action
- Press stop button (9). Automatic operation LED (8) goes out and the compressor stops
after a programmed number of seconds of unloaded operation (programmed stop time).
- To stop the compressor in the event of an emergency, press emergency stop button
(10). Alarm LED flashes (7).
On compressors with an Elektronikon® controller: remedy the problem cause, unlock
the button by pulling it out or by rotating it (dependent on the model) and press the
Escape button (5) to reset.
On compressors with an Elektronikon® Graphic controller:
Remedy the problem cause and unlock the button by pulling it out or by rotating it
(dependent on the model).
Navigate to the Stop icon on the display by means of the navigation keys (3/4) and
press the Select key.
Press reset.
Do not use emergency stop button (10) for normal stopping!
- Close air outlet valve (AV), see section Introduction.