To display the service timer, press Scroll buttons (12) to scroll to <d.6>: the service symbol is shown.
Next, press the Enter button (13). The reading of the service timer is shown in <hrs> (or <x1000 hrs> if the
service timer value is higher than 9999).
Example of the service timer screen
The example screen shows that the service timer is at 4002 hours.
Actions to be taken:
Stop the compressor, switch off the voltage and carry out the required service actions. See section
Preventive Maintenance.
The longer interval service actions must also include the shorter interval actions.
In the example above, carry out all service operations belonging to the 8000
running hours interval as well as those belonging to the 4000 running hours
interval.
The setting of the service timer can be changed in function of the operating
conditions. See section Preventive Maintenance schedule.
After servicing, reset the service timer. See section Calling up/resetting the service timer
7.8 Scrolling through all screens
Control panel
Control panel
Scroll buttons (12) can be used to scroll through all screens. The screens are divided into register screens,
measured data screens, digital input screens (numbered as <d.in>, <d.1>, ...), parameter screens (numbered
as <P.1>, <P.2>, ...), protections screens (numbered as <Pr.1>,...) and test screens (numbered as <t.1>,...).
Instruction book
32 2920 7140 90

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco GA 18 and is the answer not in the manual?

Atlas Copco GA 18 Specifications

General IconGeneral
ModelGA 18
CategoryCompressor
FAD1.8 m³/min
TypeScrew Compressor
Free Air Delivery1.8 m³/min