POWER FOCUS 600 EN Product Information
© Atlas Copco Industrial Technique AB - 9836 6534 01
5
The power consumption in idle mode has been measured with no controller accessories connected.
Mains fuse
Recommended mains fuses (power outlet):
Tool Mains voltage [V] Fuse [A]
ES21/ES61 115 15
230 16
If you are running Power Focus as a stand alone unit and trigger the tools manually (random) it is normally
possible to connect up to three Power Focus units to one power drop. If you are synchronising the spin-
dles you will need one drop for each Power Focus unit. The fusing in the power drop shall be of time delay
type.
Network Connections
Factory LAN - 100/100 Mb/s
Service LAN - 100/100 Mb/s
Network Connections
Factory LAN - 100/100 Mb/s
Service LAN - 100/100 Mb/s
Normal Environmental Conditions
This product is designed to be safe under the following conditions:
■
Indoor use
■
Altitude up to 2 000 m
■
Operating temperature +5.0 °C / +41.0 °F to +50.0 °C / +122.0 °F
■
Storage temperature +5.0 °C / +41.0 °F to +50.0 °C / +122.0 °F
■
Maximum relative humidity 80 % for temperatures up to 31 °C / 89 °F decreasing linearly to 50 % rel-
ative humidity at 40 °C / 104 °F
■
Mains supply voltage fluctuations up to ±10 % of the nominal voltage
■
Transient overvoltages up to the levels of overvoltage category ll
■
Temporary overvoltages occurring on the mains supply
■
Pollution degree 2
■
Ingress protection rating:
Technical Product Data
Technical Product Data can be found on either ServAid, or the Atlas Copco website.
Please visit: https://servaid.atlascopco.com or www.atlascopco.com.
Service Overview
Service recommendations
Preventive maintenance is recommended at regular intervals. See the detailed information on preventive
maintenance. If the product is not working properly, take it out of service and inspect it.
If no detailed information about preventive maintenance is included, follow these general guidelines:
■
Replace any defective or worn parts