- 48 -
Alternator
Measure alternator insulation resistance (11) x
Check electrical system cables for wear xxx
General
Check control panel for alarms and warnings x
Check/test emergency stop (12) x x x x
Check on abnormal noise xxxx
Test Earth Leakage Relay (12) x x x x
Drain condensate and water from spillage-free frame or
catch basin (8)
xxxx
Grease locks and hinges xxxx
Inspection by Atlas Copco service technician x x x x
Undercarriage
Check tyre pressure x x x x
Check tyres for uneven wear xx
Check torque of wheel nuts x x x
Check coupling head x xx
Check height of adjusting facility x x
Check towbar handbrake lever spring actuator,
reversing lever, linkage and all movable parts for ease of
movement
xx x x x
Maintenance schedule Daily
50 hrs
after initial
start-up
Every 500
hours
Every 1000
hours
Every 2000
hours
Yearly
Service pak - - 2912 4546 05 1636 3103 37 1636 3103 38 -

Table of Contents