Questions and Answers

  • M
    michaelmoralesAug 20, 2025
    What to do if my Atmos C 21 has weak suction?
    • S
      Steven KimAug 20, 2025
      If your Atmos Air Compressor exhibits weak suction, several factors could be responsible. First, the suction hose might be clogged, in which case you should rinse it with water. Also, make sure that the lid of the secretion canister is closed properly and check the filling level in the secretion canister. The bacterial filter may also be clogged and require replacement. Check hose connections for leaks and seal or replace them as needed. Also, inspect connecting hoses in the secretion canister compartment for breaks or kinks. If secretion has penetrated the suction pump, have it cleaned by a service technician.
  • J
    Jacob AlvaradoAug 22, 2025
    What to do if my Atmos Air Compressor is not starting?
    • T
      Tony BlackAug 22, 2025
      If your Atmos Air Compressor isn't starting, begin by checking the voltage supply to ensure it's adequate. If the voltage is fine, the unit may have an electrical defect, which requires inspection by a service technician.
  • E
    Erica ColeAug 23, 2025
    Why is there no suction on my Atmos C 21, but the vacuum gauge indicates -0.7 bar?
    • L
      Leslie McfarlandAug 25, 2025
      If your Atmos Air Compressor shows no suction, yet the vacuum gauge reads -0.7 bar, several issues could be at play. The suction hose might be clogged, requiring rinsing with water. Check the filling level in the secretion canister and ensure the float of overflow safety is not closing the suction opening. A clogged bacterial filter could also be the cause, so replace it if necessary. Inspect the connecting hoses in the secretion canister compartment for any breaks or kinks. Finally, the overflow safety might be closed; in this case, hang up the suction attachment, open the regulating valve, and tap the secretion canister to allow the floats of the overflow safety to drop back into their resting position.
  • M
    meagan87Aug 26, 2025
    What to do if my Atmos Air Compressor has no suction and the suction motor doesn't start?
    • L
      Lisa VaughnAug 26, 2025
      If your Atmos Air Compressor has no suction and the suction motor isn't starting, the photoelectric barrier or electronics may be defective, or the photoelectric barrier may be polluted. Try cleaning the photoelectric barrier. If the problem persists, have the photoelectric barrier checked by a service technician.
  • R
    Roberto WilsonAug 28, 2025
    Why Atmos C 21 has no light?
    • D
      donald02Aug 28, 2025
      If your Atmos Air Compressor has no light, first check the mains voltage and fuses to ensure there is voltage. If the voltage is correct, the light guide may have been swapped, activating a different light channel. Ensure that the light guide is positioned correctly.
  • W
    walshmarkAug 30, 2025
    Why is the pressure of compressed air too low on my Atmos Air Compressor?
    • N
      Nathan WardAug 30, 2025
      If the compressed air pressure is too low (below 2.3 bar) on your Atmos Air Compressor, start by checking the hose connections for leaks. If you find any leaks, check hose connections. If the issue persists, have a service technician check the hose connections inside the unit.
  • M
    Michelle RiveraSep 1, 2025
    What to do if the rinsing canister is overflowing on my Atmos C 21?
    • K
      kcoleSep 1, 2025
      If the rinsing canister is overflowing on your Atmos Air Compressor, the float switch may be blocked. Clean the float hose to re-establish free movement of the float. If the issue persists, the float switch may be defective, and you should inform a service technician.
  • J
    Jason CarterSep 2, 2025
    Why is my Atmos C 21 not sucking off secretion?
    • K
      Kimberly MartinezSep 2, 2025
      If your Atmos Air Compressor is no longer sucking off secretion, the electrode may be contaminated. Switch off the unit and clean the electrode. If the problem persists, the tube pump may be defective, requiring you to replace the tube cassette.
  • K
    Karen FieldsSep 4, 2025
    Why is my Atmos C 21 Air Compressor not switching off the compressed air?
    • M
      Michele McfarlandSep 4, 2025
      If the compressed air on your Atmos Air Compressor does not switch off, the photoelectric barrier may be polluted or defective. Clean the photoelectric barrier. If that doesn't resolve the issue, have the photoelectric barrier replaced by a service technician.
  • S
    Samuel RossSep 7, 2025
    What to do if the main switch is activated, but there is no voltage at the Atmos Air Compressor?
    • D
      Daniel WrightSep 7, 2025
      If the main switch is activated, but there is no voltage at your Atmos Air Compressor, and the pilot lamps do not light up, first check the fuse in the building. You can also connect other units (like a lamp) to the socket to test it. If the issue persists, the fuse on the rear of the unit may be blown. Replace the fuse.

Summary

1.0 Introduction

1.2 Intended use

Details the application and target users for the ATMOS C 21 / C 31 ENT unit.

2.0 For your safety

3.0 Setting up and starting up

3.3 Connection to electrical power line

Instructions for connecting the ATMOS C 21 / C 31 to the electrical power supply.

3.6 Starting up

Outlines the steps for starting up the ATMOS C 21 / C 31 unit.

4.0 Operation

4.2 Basic functions

Details essential functions like main switch, loads, covering, and suction system.

5.0 Cleaning and care

5.1 General information on cleaning and disinfection

General guidelines and precautions for cleaning and disinfecting the unit and parts.

5.2 Recommended instrument disinfectants

Lists recommended disinfectants for manual and automatic instrument disinfection.

6.0 Maintenance and Service

7.0 Troubleshooting

7.2 Power supply

Lists possible causes and remedies for power supply issues.

7.4 Suction system

Addresses common problems with the suction system and their solutions.

9.0 Technical data

11.0 Hygiene Plan