Questions and Answers

  • J
    James BakerSep 8, 2025
    What to do if my Atmos C 21 Air Compressor has no suction and the suction motor fails to start although compressed-air pump starts?
    • W
      whitney29Sep 8, 2025
      If there is no suction, and the suction motor fails to start even though the compressed-air pump starts on your Atmos Air Compressor, the compressed-air handle and suction hose may be transposed in the handle support. Position the handles corresponding to their switching function.
  • C
    Curtis ElliottSep 12, 2025
    Why is my Atmos C 21 Air Compressor sprayer not working?
    • M
      moodyfrederickSep 12, 2025
      If the sprayer on your Atmos Air Compressor is not working, it may be clogged. Clean the sprayer.
  • R
    Ricky LyonsSep 13, 2025
    Why is the mirror not warming up with the mirror preheater on my Atmos C 21 Air Compressor?
    • D
      Daniel Villarreal PhDSep 13, 2025
      If the mirror is not warming up with the mirror preheater, first check the voltage by connecting other consuming devices. If there is no voltage, the heating coil may be defective and needs replacement. The switch or control unit may also be defective, requiring service to exchange it.
  • N
    Nicholas BoyerSep 14, 2025
    Why does the mirror preheater remain cold on my Atmos C 21 Air Compressor?
    • J
      Julia SimpsonSep 15, 2025
      If the mirror preheater remains cold, the heating plate body in the mirror preheater plate may be defective, requiring a service technician to replace it. Also, check the voltage by connecting other consuming devices to ensure there is voltage.
  • P
    Phillip BurtonSep 16, 2025
    Why are the endoscope supports no longer heated on my Atmos C 21 Air Compressor?
    • S
      shawn66Sep 17, 2025
      If the endoscope supports are no longer heated on your Atmos Air Compressor, the overtemperature protection switch may have been activated. Have the switch, control, or sensor exchanged by your service technician.

Summary

1.0 Introduction

1.2 Intended use

Details the application and target users for the ATMOS C 21 / C 31 ENT unit.

2.0 For your safety

3.0 Setting up and starting up

3.3 Connection to electrical power line

Instructions for connecting the ATMOS C 21 / C 31 to the electrical power supply.

3.6 Starting up

Outlines the steps for starting up the ATMOS C 21 / C 31 unit.

4.0 Operation

4.2 Basic functions

Details essential functions like main switch, loads, covering, and suction system.

5.0 Cleaning and care

5.1 General information on cleaning and disinfection

General guidelines and precautions for cleaning and disinfecting the unit and parts.

5.2 Recommended instrument disinfectants

Lists recommended disinfectants for manual and automatic instrument disinfection.

6.0 Maintenance and Service

7.0 Troubleshooting

7.2 Power supply

Lists possible causes and remedies for power supply issues.

7.4 Suction system

Addresses common problems with the suction system and their solutions.

9.0 Technical data

11.0 Hygiene Plan

Atmos C 21 Specifications

General IconGeneral
BrandAtmos
ModelC 21
CategoryAir Compressor
LanguageEnglish