Mediant 2000
Mediant 2000 16 Document #: LTRT-70105
3 Configuring the Mediant 2000
The Mediant 2000 is supplied with application software already resident in its flash memory (with
factory default parameters).
Section
3.1 below describes how to assign IP addresses to the Mediant 2000, while Section 3.4
on page 20 describes how to set up the Mediant 2000 with basic parameters using a standard
Web browser (such as Microsoft
TM
Internet Explorer).
Note: Section 3.1 applies equally to MGCP, MEGACO, H.323 and SIP.
3.1 Assigning the Mediant 2000 IP Address
The Mediant 2000 is composed of one or two identical media gateway modules. These media
gateways are fully independent, each gateway having its own MAC and IP addresses (Table
3-1
shows the default IP addresses of the Mediant 2000). To assign an IP address to each of the
Mediant 2000 modules use one of the following methods:
• HTTP using a Web browser (refer to Section 3.1.1 below).
• BootP (refer to Section
3.1.2 on page 17).
• DHCP (refer to the Mediant 2000 User’s Manual).
• The embedded Command Line Interface (CLI) accessed via Telnet (refer to Section
3.1.3 on
page 18).
Use the ‘Reset’ button at any time to restore the Mediant 2000 networking parameters to their
factory default values (refer to Section
3.2 on page 19).
Table
3-1: Mediant 2000 Default Networking Parameters
Mediant 2000 Version Default Value
Single module (up to 8 Trunks)
10.1.10.10
Double module (up to 16 Trunks)
10.1.10.10 (Trunks 1-8) and 10.1.10.11 (Trunks 9-16)
Default subnet mask is 255.255.0.0, default gateway IP address is 0.0.0.0
3.1.1 Assigning an IP Address Using HTTP
¾ To assign an IP address using HTTP, take these 9 steps:
1. Disconnect the Mediant 2000 from the network and reconnect it to your PC using one of the
following two methods:
¾ Use a standard Ethernet cable to connect the network interface on your PC to a port on
a network hub / switch. Use a second standard Ethernet cable to connect the Mediant
2000 to another port on the same network hub / switch.
¾ Use an Ethernet cross-over cable to directly connect the network interface on your PC
to the Mediant 2000.
2. Change your PC’s IP address and subnet mask to correspond with the Mediant 2000 factory
default IP address and subnet mask, shown in Table
3-1. For details on changing the IP
address and subnet mask of your PC, refer to Windows™ Online Help (Start>Help).