EasyManuals Logo

AUMA SAV Series User Manual

AUMA SAV Series
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #75 background imageLoading...
Page #75 background image
Electromechanical control unit
Counter gear mechanism for end positions OPEN and CLOSED
Turns per stroke: 2 to 500 (standard) or 2 to 5,000 (option)
Limit switching
Single switch (1 NC and 1 NO) for each end position, not galvanically isolatedStandard:
Tandem switch (2 NC and 2 NO) for each end position, switches galvanically isolated
Triple switch (3 NC and 3 NO) for each end position, switches galvanically isolated
Intermediate position switches (DUO limit switching), adjustable for each direction of op-
eration
Options:
Torque switching adjustable for directions OPEN and CLOSETorque switching
Single switch (1 NC and 1 NO) silver contact (Ag) for each direction, not galvanically
isolated
Standard:
Tandem switch (2 NC and 2 NO) for each direction, switches galvanically isolatedOptions:
Silver (Ag)Standard:Switch contact material
Gold (Au), recommended for low voltage actuator controlsOptions:
Potentiometer or 0/4 20 mA (electronic position transmitter)Position feedback signal, analogue
(option)
Continuous indication, adjustable indicator disc with symbols OPEN and CLOSEDMechanical position indicator (op-
tion)
Blinker transmitter (option for modulating actuators)Running indication
Resistance type heater with 5 W, 24 V ACHeater in switch compartment
Electronic control unit (option)
Magnetic limit and torque transmitter (MWG)
Turns per stroke: 1 to 500 (standard) or 10 to 5,000 (option)
Non-Intrusive setting
Via actuator controlsPosition feedback signal
Via actuator controlsTorque feedback signal
Continuous self-adjusting indication with symbols OPEN and CLOSEDMechanical position indicator
Blinking signal via actuator controlsRunning indication
Resistance type heater with 5 W, 24 V ACHeater in switch compartment
Service conditions
Indoor and outdoor use permissibleUse
Any positionMounting position
2 000 m above sea level
> 2,000 m above sea level on request
Installation altitude
30 °C to +70 °CStandard:Ambient temperature
40 °C to +70 °C
60 °C to +60 °C
Options:
For exact version, refer to actuator name plate.
Up to 100 % relative humidity across the entire permissible temperature rangeHumidity
IP68 with AUMA 3-phase AC motor
For special motors differing enclosure protection available (refer to motor name plate)
Standard:Enclosure protection according to
EN 60529
DS terminal compartment additionally sealed against interior of actuator (double sealed)Option:
According to AUMA definition, enclosure protection IP68 meets the following requirements:
Depth of water: maximum 8 m head of water
Duration of continuous immersion in water: Max. 96 hours
Up to 10 operations during continuous immersion
Modulating duty is not possible during continuous immersion.
For exact version, refer to actuator name plate.
Pollution degree 4 (when closed), pollution degree 2 (internal)Pollution degree according to IEC
60664-1
75
SAV 07.2 SAV 16.2 / SARV 07.2 SARV 16.2 Control unit: electronic (MWG)
ACV 01.2 Modbus TCP/IP Technical data

Table of Contents

Other manuals for AUMA SAV Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AUMA SAV Series and is the answer not in the manual?

AUMA SAV Series Specifications

General IconGeneral
BrandAUMA
ModelSAV Series
CategoryController
LanguageEnglish

Related product manuals