EasyManua.ls Logo

Autotrol Logix 764 - Salt Setting

Autotrol Logix 764
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
Salt Setting
The default P6 salt setting is set at 9 lbs/cu ft. Under
normal circumstances this setting will provide the
correct system capacity. This setting may be adjusted to
change the exchange capacity.
Table 4 Exchange Capacity 255 Valv e
*Default setting.
Salt Setting
lbs/cu ft
Exchange
Capacity
grains/cu ft
Salt Setting
grams/Liter
Exchange
Capacity
grams/Liter
3 14100 50 33.6
4 18307 60 40.0
5 21160 70 44.5
6 23490 80 48.4
7 25460 90 51.8
8 27167 100 54.9
9* 28673 110 57.7
10 30019 120 60.2
11 31238 130 62.6
12 32350 140 64.8
13 33373 150 66.8
14 34320 170 70.4
15 35202 200 75.2
16 26027 230 79.3
17 26802 260 82.9
18 37533 290 86.1

Related product manuals