Customizable system parameters for SIP-based 9600 Series IP Deskphones
Issue 3 January 2014 93
PHNLDLENGTH 10 Length of national telephone number. The number
of digits in the longest possible national telephone
number. Range: 5 to 15. Needed to for "Enhanced
Local Dialing Algorithm".
PHNMUTEALERT_BLOCK 1 Blocks/unblocks the Mute Alert feature. Valid
values are:
0 = Unblocked/Allowed; allows a 9621G/9641G
end user to set mute alerting via the Home screen
Settings menu.
1 = Blocked; mute alerting not allowed.
PHNOL 9 Outside line access code. The character(s) dialed,
including # and *, if any, to access public network
local trunks. Range: 0-2 dialable numeric digits,
including " " (Null).
PHNNUMOFSA 3 When ENABLE_AVAYA_ENVIRONMENT=0, this
value sets the number of Session Appearances.
When the deskphone is in AST environment
(registered to a proxy with PPM server and Avaya
Communication Manager on the background), the
deskphone will use the number of call appearances
sent by PPM (i.e. call-appearance provisioned on
Communication Manager). In case this parameter
is set the deskphone updates this parameter and
uses it after failover to a secondary proxy. In this
case, PPM will have a higher priority than the
settings file for this parameter.
When the primary controller is set as a non-AST
proxy (a proxy without PPM and no Communication
Manager in the background, the deskphone is in a
non-AST environment); in this case the deskphone
used this parameter to set its call-appearance.
PHONE_LOCK_IDLETIME 0 Sets the idle time (in minutes) before the
deskphone locks itself. The range is from 0 to
10080. If set to 0, the deskphone never locks.
PHY1STAT 1 Ethernet line interface setting. The values are:
1=auto-negotiate, 2=10Mbps half-duplex,
3=10Mbps full-duplex, 4=100Mbps half-duplex,
5=100Mbps full-duplex.
PHY2PRIO 0 Layer 2 priority value for frames received on or
forwarded to the secondary Ethernet interface. Set
this parameter only when VLAN separation is "1"
(enabled). Values are from 0-7 and correspond to
the drop-down menu selection.
Parameter Name Default
Value