EasyManua.ls Logo

Avaya Converged Platform 130 Series - Power Requirements

Avaya Converged Platform 130 Series
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 7: Standard operating temperature
Standard operating temperature Specifications
Continuous operation (for altitude less than
950 m or 3117 ft)
5°C–40°C (41°F–104°F) with no direct sunlight on the
equipment.
Power requirements
The system supports up to two AC power supply units (PSU).
Table 8: PSU specifications
PSU Class Heat dissipation
(maximum)
Frequency Voltage
750 W AC Platinum 2891 BTU/hr 50/60 Hz 100–240 V AC, autoranging
Table 9: ACP 100 Series - Dell R640 Power Requirements
ACP100 Series Dell R640 System VA rating Heat Output (BTU/hr) Peak Power Max.
(Watts)
Profile 2 200 680 270
Profile 3 340 1161 457
Profile 4 283 1066 365
Profile 5 504 1721 655
Profile 51 528 1802 685
Power requirements
October 2019 Installing the Avaya Converged Platform 130 Series 19
Comments on this document? infodev@avaya.com