AXIS M3014 - System Options
Network
Basic TCP/IP Settings
AXIS M3014 support both IP version 4 and IP version 6. Both versions may be enabled simultaneously, and at least one version
must always be enabled. When using IPv4, the IP address for the camera can be set automatically via DHCP, or a static IP
address can be set manually. If IPv6 is enabled, the network cameras receive an IP address according to the configuration in
the network router. There are also options for setting up notification of changes in the IP address, and for using the AXIS
Internet Dynamic DNS Service. For more information on setting the IP address, please see the online help .
Network Settings - Click the View button for an overview of the IP configuration of the network camera.
IPv4 Address Configuration - Check the Enable IPv4 box option to enable IPv4.
Obtain IP address via DHCP - Dynamic Host Configuration Protocol (DHCP) is a protocol that lets network administrators
centrally manage and automate the assignment of IP addresses on a network. DHCP is enabled by default. Although a DHCP
server is mostly used to set an IP address dynamically, it is also possible to use it to set a static, known IP address for a
particular MAC address.
Note:
DHCP should
only be enabled if your DHCP server can update a DNS server, which then allows you to access the AXIS
M3014 Network Camera by name (host name). If DHCP is enabled and you cannot access the unit, run AXIS IP Utility
to search the network for connected Axis products or reset the network camera to factory default settings and then
perform the installation again.
Use the following IP address - To use a static IP address for the AXIS M3014 Network Camera, check the radio button
and then make the following settings:
IP addr
ess - Specify a unique IP address for your AXIS M3014 Network Camera. (To check if the IP address you intend
to use is available or not, click the Test button)
Subnet mask - Specif
y the mask for the subnet the AXIS M3014 Network Camera is located on
Defaul
t router - Specify the IP address of the default router (gateway) used for connecting devices attached to differ-
ent networks and network segments.
IPv6 Address Configuration - Check the Enable IPv6 box option to enable IPv6. Other settings for IPv6 are configured in
the network router.
Services - Enable ARP/Ping setting of IP address - The IP address can be set using the ARP/Ping method, which associates
the unit's MAC address with an IP address. Check this box to enable the service. Leave disabled to prevent unintentional
resetting of the IP address.
Notes:
The ARP/Ping service is automatically disabled two minutes after the unit
is started, or as soon as an IP address is set.
In order to reset the IP address, the camera must be restarted to activate ARP/Ping for an additional two minutes.
Pinging the unit is still possible when this service is disabled.

Other manuals for Axis M3014

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Axis M3014 and is the answer not in the manual?

Axis M3014 Specifications

General IconGeneral
Total megapixels1 MP
Maximum resolution1280 x 800 pixels
Video formats supportedH.264, M-JPEG
Minimum illumination1 lx
Sensor typeCMOS
Progressive scanYes
Optical sensor size1/4 \
Effective sensor resolution1000000 pixels
Lens diameter2.9 mm
Cabling technology10/100Base-T(X)
Supported network protocolsIPv4/v6, HTTP, HTTPS, QoS Layer 3 DiffServ, FTP, SMTP, Bonjour, UPnP, SNMPv1/v2c/v3(MIB-II), DNS, DynDNS, NTP, RTSP, RTP, TCP, UDP, IGMP, RTCP, ICMP, DHCP, ARP, SOCKS
Power source typePoE
Ethernet LAN (RJ-45) ports1
CertificationEN 55022 B, EN 61000-3-2, EN 61000-3-3, EN 55024, FCC Part 15 Subpart B B, ICES-003 B, VCCI B, C-tick AS/NZS CISPR 22, MIC B, EN 60950-1 AXIS M3014: KCC B
Processor modelARTPEC-3
Placement supportedIndoor & outdoor
Mounting typeCeiling
Flash memory128 MB
Operating temperature (T-T)0 - 45 °C
Operating relative humidity (H-H)20 - 80 %
Weight and Dimensions IconWeight and Dimensions
Weight260 g

Related product manuals