AXIS P3344 Fixed Dome Network Camera
Hardware overview
ConnectingtoAXISInternetDynamicDNSService. Seepage 40. To connect, press and hold the button for
about 3 seconds.
Resetting the product to factory default settings. See page 47.
I/O connector
Note
For technical specications, se e page 53.
I/O terminal connector - Use in applications for e.g. motion detection, event triggering, time lapse recording and alarm notications.
In addition to an auxiliary power and a GND pin, the I/O terminal connector provides the interface to:
Digital output For connecting external devices such as relays and LEDs. Connected devices can be activated by
the VAPIX® Application Programming Interface, output b uttons on the Live View page or by an Action Rule. The
output will show as active (shown under System Options > Ports & Devices) if the alarm device is activated.
Digital input An alarm input for connecting devices that ca n toggle between an open and closed circuit, for
example: PIRs, door/window contacts, glass break detectors, e tc. When a signal is received the state changes and
the input becomes a ctive (shown under System Options > Ports & Devices).
Note
The I/O connector is connected to the housing (fan/heater) on delivery, and w ill trigger an input port event to indicate
a fan or heater error when activated. See Events, on page 32 for information on how to set up an event.
Function Pin Notes
Specications
GND
1
Ground
3.3 V DC Power
2
Can be used to power auxili ary equipment.
Note: This pin can only be used as power out.
Max load = 50 mA
Digital Input
3
Connect to GND to activate, or leave oating (unconnected)
to deactivate.
0to+40VDC
Digital Output
4
Internal connection to ground when activated, oating
(unconnected) when deactivated. If used with an inductive
load, e.g. a relay, a diode must be connected in parallel with
the load, for protection aga inst voltage transients.
Max l oad =100 mA
Max voltage = +40 V DC
6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Axis P3344 and is the answer not in the manual?

Axis P3344 Specifications

General IconGeneral
Maximum resolution1280 x 800 pixels
Pan range0 - 360 °
Tilt angle range0 - 170 °
Angle of rotation340 °
Camera shutter speed1/25000 - 1/6 s
Minimum illumination0.4 lx
Sensor typeCMOS
Optical sensor size1/4 \
Focal length range3.3 - 12 mm
Video motion detectionYes
Power source typePoE
I/O portsRJ-45
Dimensions (WxDxH)96 x 96 x 148 mm
Processor modelARTPEC-3
Flash memory128 MB
Supported network protocolsIPv4/v6, HTTP, HTTPS, QoS Layer 3 DiffServ, FTP, SMTP, Bonjour, UPnP, SNMPv1/v2c/v3(MIB-II), DNS, DynDNS, NTP, RTSP, RTP, TCP, UDP, IGMP, RTCP, ICMP, DHCP, ARP, SOCKS.
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)20 - 80 %
Weight and Dimensions IconWeight and Dimensions
Weight445 g