Configuration AXIS Panorama PTZ User’s Manual
18
Reinstating the Factory Default Settings
In certain circumstances, it may be necessary to reinstate the Factory Default settings for
your AXIS Panorama PTZ. This is performed by clicking the Support link in the
Administration Tools and then selecting Restart/Reset, or by pressing the Control Button.
Follow the instructions below to reinstate the product factory default settings using the
Control button:
1. Switch off the AXIS Panorama PTZ by disconnecting the power cable.
2. Press and keep the Control Button pressed, and then reconnect the power cable.
3. Keep the Control Button pressed until the Status Indicator displays yellow (note that
this may take up to 15 seconds), then release the button. When the Status Indicator
displays green (which can take up to 1 minute) the AXIS Panorama PTZ will then have
been reset to the original factory default settings.
Notes: •Reinstating the original default settings will cause all parameters (including the IP address) to
be reset.
•Refer to Network Installation, on page 10, for information on how to set the camera’s IP
address.