9-6
Chapter 9. LIST OF COMMUNICATION DATA
Bank
Item name
RAM address EEPROM address RAM EEPROM
Decimal
point
information
Notes
Decimal
Hexadecimal
Decimal
Hexadecimal
Read Write Read Write
DO
Assignment
Event output 3 Operation type
5645 160D 22029 560D
Event output 3 Output assignment A
5646 160E 22030 560E
Event output 3 Output assignment B
5647 160F 22031 560F
Event output 3 Output assignment C
5648 1610 22032 5610
Event output 3 Output assignment D
5649 1611 22033 5611
Event output 3 Polarity A
5650 1612 22034 5612
Event output 3 Polarity B
5651 1613 22035 5613
Event output 3 Polarity C
5652 1614 22036 5614
Event output 3 Polarity D
5653 1615 22037 5615
Event output 3 Polarity
5654 1616 22038 5616
Event output 3 Latch
5655 1617 22039 5617
Event
Configuration
Internal Event 1 Operation type
5801 16A9 22185 56A9
Internal Event 1 Direct/Reverse
5802 16AA 22186 56AA
Internal Event 1 Standby
5803 16AB 22187 56AB
Internal Event 1 state at READY
5804 16AC 22188 56AC
(Reserved for future extension.)
5805 16AD 22189 56AD
Internal Event 1 Alarm OR
5806 16AE 22190 56AE
Internal Event 1 Special OFF
5807 16AF 22191 56AF
Internal Event 1 Delay time unit
5808 16B0 22192 56B0
(Reserved for future extension.)
5809 16B1 22193 56B1
Internal Event 2 Operation type
5810 16B2 22194 56B2
Internal Event 2 Direct/Reverse
5811 16B3 22195 56B3
Internal Event 2 Standby
5812 16B4 22196 56B4
Internal Event 2 state at READY
5813 16B5 22197 56B5
(Reserved for future extension.)
5814 16B6 22198 56B6
Internal Event 2 Alarm OR
5815 16B7 22199 56B7
Internal Event 2 Special OFF
5816 16B8 22200 56B8
Internal Event 2 Delay time unit
5817 16B9 22201 56B9
(Reserved for future extension.)
5818 16BA 22202 56BA
Internal Event 3 Operation type
5819 16BB 22203 56BB
Internal Event 3 Direct/Reverse
5820 16BC 22204 56BC
Internal Event 3 Standby
5821 16BD 22205 56BD
Internal Event 3 state at READY
5822 16BE 22206 56BE
(Reserved for future extension.)
5823 16BF 22207 56BF
Internal Event 3 Alarm OR
5824 16C0 22208 56C0
Internal Event 3 Special OFF
5825 16C1 22209 56C1
Internal Event 3 Delay time unit
5826 16C2 22210 56C2
(Reserved for future extension.)
5827 16C3 22211 56C3
Internal Event 4 Operation type
5828 16C4 22212 56C4
Internal Event 4 Direct/Reverse
5829 16C5 22213 56C5
Internal Event 4 Standby
5830 16C6 22214 56C6
Internal Event 4 state at READY
5831 16C7 22215 56C7
(Reserved for future extension.)
5832 16C8 22216 56C8
Internal Event 4 Alarm OR
5833 16C9 22217 56C9
Internal Event 4 Special OFF
5834 16CA 22218 56CA
Internal Event 4 Delay time unit
5835 16CB 22219 56CB
(Reserved for future extension.)
5836 16CC 22220 56CC
Internal Event 5 Operation type
5837 16CD 22221 56CD
Internal Event 5 Direct/Reverse
5838 16CE 22222 56CE
Internal Event 5 Standby
5839 16CF 22223 56CF
(Continue on next page.)