9-7
Chapter 9. LIST OF COMMUNICATION DATA
Bank
Item name
RAM address EEPROM address RAM EEPROM
Decimal
point
information
Notes
Decimal
Hexadecimal
Decimal
Hexadecimal
Read Write Read Write
Event
Configuration
Internal Event 5 state at READY
5840 16D0 22224 56D0 —
(Reserved for future extension.)
5841 16D1 22225 56D1
∆ ∆ ∆ ∆
—
Internal Event 5 Alarm OR
5842 16D2 22226 56D2 —
Internal Event 5 Special OFF
5843 16D3 22227 56D3 —
Internal Event 5 Delay time unit
5844 16D4 22228 56D4 —
(Reserved for future extension.)
5845 16D5 22229 56D5
∆ ∆ ∆ ∆
—
Internal Event 6 Operation type
5846 16D6 22230 56D6 —
Internal Event 6 Direct/Reverse
5847 16D7 22231 56D7 —
Internal Event 6 Standby
5848 16D8 22232 56D8 —
Internal Event 6 state at READY
5849 16D9 22233 56D9 —
(Reserved for future extension.)
5850 16DA 22234 56DA
∆ ∆ ∆ ∆
—
Internal Event 6 Alarm OR
5851 16DB 22235 56DB —
Internal Event 6 Special OFF
5852 16DC 22236 56DC —
Internal Event 6 Delay time unit
5853 16DD 22237 56DD —
(Reserved for future extension.)
5854 16DE 22238 56DE
∆ ∆ ∆ ∆
—
Internal Event 7 Operation type
5855 16DF 22239 56DF —
Internal Event 7 Direct/Reverse
5856 16E0 22240 56E0 —
Internal Event 7 Standby
5857 16E1 22241 56E1 —
Internal Event 7 state at READY
5858 16E2 22242 56E2 —
(Reserved for future extension.)
5859 16E3 22243 56E3
∆ ∆ ∆ ∆
—
Internal Event 7 Alarm OR
5860 16E4 22244 56E4 —
Internal Event 7 Special OFF
5861 16E5 22245 56E5 —
Internal Event 7 Delay time unit
5862 16E6 22246 56E6 —
(Reserved for future extension.)
5863 16E7 22247 56E7
∆ ∆ ∆ ∆
—
Internal Event 8 Operation type
5864 16E8 22248 56E8 —
Internal Event 8 Direct/Reverse
5865 16E9 22249 56E9 —
Internal Event 8 Standby
5866 16EA 22250 56EA —
Internal Event 8 state at READY
5867 16EB 22251 56EB —
(Reserved for future extension.)
5868 16EC 22252 56EC
∆ ∆ ∆ ∆
—
Internal Event 8 Alarm OR
5869 16ED 22253 56ED —
Internal Event 8 Special OFF
5870 16EE 22254 56EE —
Internal Event 8 Delay time unit
5871 16EF 22255 56EF —
(Reserved for future extension.)
5872 16F0 22256 56F0
∆ ∆ ∆ ∆
—
Parameter
Control method
6001 1771 22385 5771 —
MV low limit at AT
6002 1772 22386 5772 1
MV high limit at AT
6003 1773 22387 5773 1
ON/OFF control differential
6004 1774 22388 5774 P
ON/OFF control operating point offset
6005 1775 22389 5775 P
PV filter
6006 1776 22390 5776 1
PV ratio
6007 1777 22391 5777 3
PV bias
6008 1778 22392 5778 P
RSP filter
6009 1779 22393 5779 1
RSP ratio
6010 177A 22394 577A 3
RSP bias
6011 177B 22395 577B P
Time proportional unit 1
6012 177C 22396 577C —
Time proportional cycle 1
6013 177D 22397 577D —
Time proportional unit 2
6014 177E 22398 577E —
Time proportional cycle 2
6015 177F 22399 577F —
Time proportional cycle mode
6016 1780 22400 5780 —
MV variation limit
6017 1781 22401 5781 1
(Continue on next page.)