Setup > Inputs/Output > Input
An asterisk (*) indicates the parameter default.
Input Submenus Options/Descriptions
MODE
DISABLED
Select the action to take when the input is active (based on the state).*RESET TOTAL
UNLATCH ALARM
STATE
*ACTIVE ON HIGH
Select the voltage level to make the input active.
ACTIVE ON LOW
Setup > Inputs/Output > RTD (Energy Models Only)
An asterisk (*) indicates the parameter default.
Input Submenus Options/Descriptions
TEMP SENSOR TYPE
Pt1000 2-WIRE
Select the temperature sensor type.
Pt1000 3-WIRE
Pt1000 4-WIRE
Pt100 2-WIRE
Pt100 3-WIRE
Pt100 4-WIRE
RANGE
32…122° F (0…50° C)
Select the temperature range.
32…212° F (0…100° C)
-40…392° F (-40…200° C)
4…86° F (-20…30° C)
DELTA TEMP
TEMP #1-TEMP #2
TEMP #2-TEMP #1
Select the order for positive and negative energy calculations.
TRIM RTD #1
Adjust the offset for the
temperature reading for
RTD #1.
Typically the temperature readings do not need to be calibrated in the field when
using Pt100 and Pt1000 RTDs. See Troubleshooting” on page44 before adjusting
the RTD input.
TRIM RTD #2
Adjust the offset for the
temperature reading for
RTD #2.
Parameter Descriptions by Menu
Page 35 October 2019 TTM-UM-02222-EN-04

Table of Contents

Other manuals for Badger Meter Dynasonics TFX-500w

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Badger Meter Dynasonics TFX-500w and is the answer not in the manual?

Badger Meter Dynasonics TFX-500w Specifications

General IconGeneral
BrandBadger Meter
ModelDynasonics TFX-500w
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals