EasyManua.ls Logo

Baldor MicroFlex e100 - 8 Specifications

Baldor MicroFlex e100
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.baldormotion.com
8-4 Specifications MN1942
8.1.5 Digital inputs - drive enable and DIN0 general purpose (X3)
Unit All models
Type Opto-isolated inputs
Input voltage
Nominal
Minimum
Maximum
Active
Inactive
VDC
24
12
30
>12
<2
Input current (maximum, per input) mA 50
Sampling interval ms 1
Minimum pulse width μs 5
8.1.6 Digital inputs DIN1, DIN2 - high speed general purpose (X3)
Unit All models
Type Opto-isolated inputs
Input voltage
Nominal
Minimum
Maximum
Active
Inactive
VDC
24
12
30
>12
<2
Input current (maximum, per input) mA 20
Maximum input frequency MHz 1
Minimum pulse width ns 250
8.1.7 Digital outputs DOUT0, DOUT1 - status and general purpose (X3)
Unit All models
User supply (maximum) V 28
Output current (max. continuous) mA 100
Fuse
Approximate trip current
Reset time
mA
s
200
<20
Update interval ms 1

Table of Contents