Basic Insta llation 3-9MN1942
3.3 Connector locatio n s
3.3.1 Front panel connectors
11 Status+
12 DGND
13 DOUT1+
14 DIN2+
15 DGND
16 DIN1+
17 DIN0+
18 DGND
19 Drive enable+
20 Shield
1 (NC)
2 Data-
3 Data+
4GND
X3 Input / Output
X6 RS485 port (2-wire)
USB
X8 Feedback In
X1 Power
Earth/Ground
Earth/Ground
(NC)
L1 AC Phase 1 / L
L2 AC Phase 2 / N
L3 AC Phase 3
U Motor U
V Motor V
W Motor W
R1 Regen
R2 Regen
Pin Incremental SinCos BiSS / SSI EnDat
1 CHA+ (NC) Data+ Data+
2 CHB+ (NC) Clock+ Clock+
3 CHZ+ (NC) (NC) (NC)
4 Sense Sense Sense Sense
5HallU-Sin- (NC) Sin-*
6HallU+Sin+ (NC) Sin+*
7HallV-Cos- (NC) Cos-*
8HallV+Cos+ (NC) Cos+*
9 CHA- (NC) Data- Data-
10 CHB- (NC) Clock- Clock-
11 CHZ- (NC) (NC) (NC)
12 +5 V out +5 V out +5 V out +5 V out
13 DGND DGND DGND DGND
14 Hall W- (NC) (NC) (NC)
15 Hall W+ (NC) (NC) (NC)
Shell Shi eld S hield Shield Shield
1 Status-
2DGND
3DOUT1-
4DIN2-
5DGND
6DIN1-
7DIN0-
8DGND
9 Drive enable-
10 Shield
0V
+24 V
X2 Control circuit power
* EnDat v2.1 only. EnDat v2.2 does not use the Sin and
Cos signals.
Node ID
These switches set the Mi croFlex e100’s
node ID for ETHERNET Powerlink, and the
final value of the IP address when using
TCP/IP. See sections 5.7.1 and 6.2.4.
(NC) = Not Connected. Do not
make a connection to this pin.
LEDs
The STATUS, CAN and ETHERNET
LEDs are described in section 7.2.1.
Tightening torque for terminal bl ock connections (X1 & X2) is 0.5-0.6 N·m
(4.4-5.3 lb-in). Maximum wire sizes: X1: 2.5 mm
2
; X3: 0.5 mm
2
. Connector
X3 is designed to accept bare wires only; do not use bootlace ferrules.
1TXA
2TXB
3GND
4 +7V out
5 (NC)
6 (NC)