EasyManua.ls Logo

Baldor MicroFlex e100 - Connection Summary - Recommended System Wiring

Baldor MicroFlex e100
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.baldormotion.com
Input / Output 5-25MN1942
5.8 Connectio n summary - recommended system wiring
As an example, Figure 45 shows the recommended wiring necessary for the MicroFlex e100 to
control a motor , while conforming to the EMC requirements for ‘industrial’ environments.
2A
PC
AC power
Motor power U V W
Control circuit s upply (fused).
Use twisted pair cabl e with a
ferrite sleeve (see section 3.4.8).
Motor
+24 VDC
Notes:
1) The MicroFlex e100 should be mounted on an earthed metal back plane.
2) Ensure cables do not obstruct airflow to the heatsink.
3) Motor represents a typical Baldor BSM motor. Linear motors may also be controlled by MicroFlex e100.
4) Conductiv e shield earth/ground c lamps are not supplied.
5) The threaded holes in the top and bottom of the case are for M4 bolts no longer than 11 mm (0.43 in) in length.
6) When using single phas e supplies it may be necessary to reverse the AC power filter - see section 3.4.7.2.
0V
Filter
L1
L2
L1
L2
L3
Star
point
L1
L2
L3
Optional regen resistor
(Dynamic brake)
L3
Connect motor power cable
shield to metal backplane using
conduc tive shield cl amp
PE
From
fuses
AC power in
Motor feedback
Regen
Shielded twisted pair, c lamped to
metal backplane near drive using
conduc tive shield earth/ground
clamp (see sections 3.6 and D.1.7).
Connect AC power cabl e s hield to
metal backplane usi ng c onductive
shield clamp (see section D.1.7).
Motion controller
Drive enable
input
+24VDC 0V
Ethernet
USB
Ferrite
See
note 5
See note 5
Figure 45 - Recommended system wiring