3.1 Introduction
You should read all the sections in Basic Installation to ensure safe installation.
This section describes the mechanical and electrical installation of the MicroFlex e100 in the
following stages:
H Location considerations
H Mounting the MicroFlex e100
H Connecting the AC power supply
H Connecting the 24 VDC control circuit supply
H Connecting the motor
H Installing a regeneration resistor (Dynamic Brake)
H Connecting the feedback device
These stages should be read and followed in sequence.
3.1.1 Power sources
A 115 - 230 VAC power source (IEC1010 over-voltage category III or less) in the installation area
is required. This may be single-phase or three-phase. An AC power filter is required to comply
with the CE directive for which the MicroFlex e100 was tested (see section 3.4.7).
The 24 VDC control circuit supply must be a regulated power supply with a continuous current
supply capability of 1 A (4 A power on surge).
3.1.2 Hardware requirements
The components you will need to complete the basic installation are:
H 24 VDC power supply.
H AC power supply filter (for CE compliance).
H The motor that will be connected to the MicroFlex e100.
H A motor power cable.
H An incremental encoder feedback cable, SSI cable, or BiSS / EnDat / SinCos cable.
A separate Hall cable might also be required for linear motors.
H A USB cable.
H (Optional) A regeneration resistor (Dynamic Brake) might be required, depending on the
application. Without the regeneration resistor, the drive may produce an overvoltage fault. All
MicroFlex e100 models have overvoltage sensing circuitry . Regeneration resistors may be
purchased separately - see Appendix A.
H A cooling fan may be required to allow operation of the MicroFlex e100 at full rated current
(see section 3.2.2).