EasyManua.ls Logo

Baldor MicroFlex e100 - Sincos Feedback

Baldor MicroFlex e100
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.baldormotion.com
Feedback 4-11MN1942
4.1.4 SinCos feedback
The SinCos connections (Sin and Cos incremental channels only) are made using the 15-pin
D-type female connector X8. T wisted pair cables must be used for the complementary signal
pairs e.g. Sin+ and Sin-. The overall cable shield (screen) must be connected to the metallic shell
of the D-type connector. Connector X8 includes a ‘Sense’ pin, which is used to detect the voltage
drop on long cable runs. This allows the MicroFlex e100 to increase the encoder supply voltage
on pin 12 to maintain a 5 V supply at the encoder (200 mA max). The Sin and Cos channel input
circuits accept a nominal 1 V pk-pk sine wave centered on a 2.5 V reference.
Pin
SinCos function
1 (NC)
2 (NC)
3 (NC)
4 Sense
5 Sin-
6 Sin+
7 Cos-
8 Cos+
9 (NC)
10 (NC)
11 (NC)
12 +5 V out
13 DGND
14 (NC)
15 (NC)
Sin-
Sin+
Cos-
Cos+
+5 V out
DGND
5
6
7
8
12
X8
SinCos
Feedback
13
4 Sense
Connect overall shield to
connec tor backshells.
Twis ted pai rs
Connect internal
shields to DGND.
Motor
Figure 23 - SinCos cable connections
1
8
9
15

Table of Contents

Other manuals for Baldor MicroFlex e100