EasyManua.ls Logo

Baldor MicroFlex e100 - D.1.7 Wiring of Shielded (Screened) Cables

Baldor MicroFlex e100
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.baldormotion.com
CE & UL C-5MN1942
D.1.7 Wiring of shielded (screened) cables
Remove the outer insulation
to expose the overall shield.
Clamp should provi de 360°
contac t with the cabl e.
Flat or p-type
conduc tive clamp
Figure 62 - Earthing/grounding cable shields
1
9
2
10
3
11
12
13
MicroFlex e100
X8
Encoder Connector
Housing
Cable
Twisted pairs
Connect overall s hield
to c onnec tor backshell.
Connect overall s hield
to c onnec tor backshell.
CHA+
CHA-
CHB+
CHB-
CHZ+
CHZ-
+5 V
DGND
Figure 63 - Encoder signal cable grounding

Table of Contents

Other manuals for Baldor MicroFlex e100

Related product manuals