5. Appendices
No image appears on-screen
Ensure all the cables and power connections are correctly and se-
curely connected as described in the “Installation” section.
Check if all pins are ok in the connector.
Check if the projection lamp has been securely installed.
Make sure you have removed the lens cap and the projector is 
switched on.
Partial, scrolling or incorrectly displayed image
Press “AUTO” on control panel or “A IMG” on remote control.
If you are using a PC (for Windows 95, 98, 2000, XP, Windows 7):
Open the “My Computer” icon, the “Control Panel” folder, and 
then double click on the “Display” icon.
Select the “Settings” tab.
Verify that your display resolution setting is lower than or equal 
to WUXGA (1920 × 1200).
Click on the “Advanced Properties” button. If the projector is still 
not projecting the whole image, you will also need to change the 
monitor display you are using. Refer to the following steps.
Verify the resolution setting is lower than or equal to WUXGA 
(1920 × 1200).
Select the “Change” button under the “Monitor” tab.
Click on “Show all devices”. Next, select “Standard monitor 
types” under the SP box; choose the resolution mode you need 
under the “Models” box. 
Verify that the resolution setting of the monitor display is lower 
than or equal to WUXGA (1920 × 1200).
-
-
-
-
-
-
If you experience a problem with your projector, please refer to the follow-
ing information. If a problem persists, please contact your local reseller or 
service center. 
5.1.1  Image Problems
5.1  Troubleshooting
5.   APPENDICES
Note: This projector can not display 1920*1200 resolution but only 
1920*1200 RB (reduce blanking).