To write to the Barionet registers and change register values the SNMP write
community password (“privat”) must be set before.
To write to the Barionet´s SNMP register select one of the Barionet input (IO)
registers and select the “Set” option.
On the iReasoning MIB Browser opens now a new window, there the desired
value to write to this register can be set. In the picture below the register 1 to
set is the opposite value as it currently is (from 1 to 0).
As result the Barionet relay is switching and a “successful” message opens.
BARIX AG | 17. Oct. 2013 | Barionet Hands-on Training Guide | Page 31/38