ber of the B1290. The telephone number would then be displayed on the
pager, and the called party would receive the alarm message when he
called the B1290 back. The B1290 would have to be programmed to wait
some time for an acknowledgment before it continued dialing.
Example 7: Announcing Alarms over a Public Address System
In this example, the B1290 is used to announce alarms from an unattended
locationoverabuilding’spublicaddresssystem. Youwantthealarmstobe
announced twice, repeated again one minute later then repeated for the
lasttime one minute after this. To make theprocess stopafter thethird rep
-
etition, program Timer B to zero. A zero value in Timer B means that the
alarm is automatically acknowledged after A Times.
Connect the radio port, TX Audio and PTT, from the B1290 to the PA in
-
puts.
Starting with the timer setup.
B1290: Enter Program Code
YOU:
4**
B1290: Answer Rings is 4 (No effect on operation)
YOU:
** Next
B1290: Timer A is 2 minutes
YOU:
1** Change the timer to 1 minute
B1290: Timer A is 1 minutes
YOU:
** Next
B1290: Timer B is 10 minutes
YOU:
0** Change the timer to zero
B1290: Timer B is 0 minutes
YOU:
** Next
B1290: Times A is 3
YOU:
2** Change the times A to 2
B1290: Times A is 2
YOU:
** Next
The timers are now set, now put the commands into the directory.
B1290: Enter Program Code
YOU:
2** Directory Code