AW00118508000 Acquisition Control
Basler racer Camera Link 59
1. Set the value of the Trigger Mode Line Start register to On.
2. Set the value of the Trigger Source Line Start register to Software, CC1, CC2, CC3, or CC4.
3. If the trigger source is set to CC1, CC2, CC3, or CC4, set the value of the Trigger Activation
Line Start register to Rising Edge or Falling Edge.
1. Set the value of the Trigger Mode Line Start register to Off.
2. Set the value of the Exposure Time Raw register as desired.
3. A value in a raw register is simply an integer value with no units. To determine what the actual
setting will be, you must multiply the value in the raw register by the camera’s time base. The
time base on racer cameras is 100 ns.
4. For example, if you set the Exposure Time Raw register to 1000, the exposure time would be
100 µs (1000 x 100 ns = 100 µs).
5. Set the value of the Acquisition Line Period Enable register to 1 (true).
(This will enable the camera’s ability to internally control the line period.)
6. Set the value of the Acquisition Line Period Raw register as desired.
(Line Rate = 1 /Line Period.)
For more information about direct register access, see Section 3.2 on page 28.
To set the trigger mode to On and to select a trigger source via direct register access:
To set the trigger mode to Off, set the exposure time, and set the line acquisition rate via
direct register access:

Table of Contents

Other manuals for Basler racer

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Basler racer and is the answer not in the manual?

Basler racer Specifications

General IconGeneral
BrandBasler
Modelracer
CategoryDigital Camera
LanguageEnglish

Related product manuals