AW00118508000 Acquisition Control
Basler racer Camera Link 86
Set the value of the Line Source CL Spare register to Line Trg Ready.
For more information about direct register access, see Section 3.2 on page 28.
6.3.4 Input Related Signals as Output Signals
The camera allows selecting the output signal of the frequency converter module and assigning it
to the camera’s CL Spare output line. In this fashion input signals can be passed through a camera
to trigger additional cameras.
In this case, setting a minimum output pulse width may be necessary to ensure output signal
detection.
For more information about selecting the source signal for the CL Spare output line on the camera,
see Section 5.5.2.3 on page 49.
For more information about the minimum output pulse width feature, see Section 5.5.2.1 on
page 48.
To select the line trigger wait signal as the source signal for the CL Spare line via direct
register access: