Maintenance Manual of 4M11 Series Diesel Engine For Land Power Generators
96
4.8.3.3 Inspection and Maintenance of Thermostat
Check the clamps for failure. If any, replace them.
Check the coolant hoses for cracks. If any, replace them .
Check the thermostat for breakage. If any, replace it.
4.8.3.4 Thermostat Assembly Procedures
Assembly is in the reverse order of disassembly.
The initial opening temperature is 76ºC and the full-opening temperature is 90ºC for the thermostat.
4.8.4 Disassembly, Inspection, Repair, and Assembly of Fan
4.8.4.1 Exploded View for Assembly of Fan
Figure 4-63 Exploded View for Assembly of Fan
4.8.4.2 Fan DisassemblyProcedures
As shown in Figure 4-55:
Disassemble the connecting bolts and type 2 full-metal hexagon lock nuts between fan and fan
hub assembly and disassemble the fan.
Disassemble the studs and type 2 full-metal hexagon lock nuts between fan hub assembly and
crankshaft pulley and disassemble the fan hub assembly.
Disassemble the pulley.
4.8.4.3 Inspection and Maintenance of Fan
Observe the fan, fan hub assembly, and pulley for presence of damage (such as cracking). If yes,
replace.
4.8.4.4 Fan Assembly Procedures
Assembly is in the reverse order of disassembly.
Water pump
intermediate
p
a
d
Hose
Water pump
p
ulle
y
Intermediat
e flange
Flat
Hex
socket-head
screw
Spring
washer
Fan
Belt
Water pu mp
inlet pipe
Water
p
ump
gasket
Hose
Water
p
ump
Water
p
ump
gasket