Abb. 33
Abb. 34
Abb. 35
Instruction Manual Breathing Air Compressors
24
Setup
To enter the setup for the different functions of the B-Timer
press the and keys on the display simultaneously for more
than 5 seconds from the cartridge number display (Abb. 33).
Filter symbol starts flashing (Abb. 31) indicating the setup
mode.
Under setup A the filter cartridge number is set. To change
cartridge type, press key for 3 seconds, the number starts
flashing. Press the key to select the correct number, press
key to accept the new setting.
Numbers beginning with 999 require a
special adjustment:
Press key for 3 seconds. Press the key to select 999000, the
last 0 starts flashing. Press the key to select the correct
number, then press key: the second 0 will start flashing, pro
ceed as above and finally adjust the 3rd 0 accordingly.
Pressing the key, display changes to setup B for the delivery
setting. Filter symbol starts flashing (Abb. 34). To change de
livery, press key for 3 seconds, the 1st digit starts flashing.
Press the key to select the correct number, press key to ac
cept the new setting. Repeat procedure for the other two di
gits
Pressing the key again, display changes to setup C for the
pressure range setting. Filter symbol starts flashing (Abb. 35).
To change pressure, press key for 3 seconds. Press the key
to select the correct pressure (200, 300 or 200/300), press
key to accept the new setting.
After finishing setup and fitting a new car
tridge, the filter capacity has absolutely to
be reset, see “Reset” above.
Pressing the key again, display changes to the menue for
adjusting the operating hours. Press key for 2 seconds,
the last digit will start flashing. Press the key to select the
correct number, then press key etc., until all digits are set.
Then pressing the key twice will lead back to the main
menue, Pressing the the key and the key gives the possi