Abb. 63 Timer K10 (electric units)
1
2
3
Adjusting the timer
(units with petrol engine; power-flow timer)
- Adjust condensate drain period (in seconds) with control
(1, Abb. 64).
- Adjust condensate drain interval (in minutes) with control
(2).
Abb. 64 Timer K10 (petrol units)
1 2
Adjusting the timer
(units with petrol engine; Bürkert timer)
Example: standard adjustment:
Condensate drain interval = 15 min.
Drain time = 6 s.
Adjust the electric timer as follows:
- Remove cover by undoing the screw.
- Ensure that DIP switches 1 to 8 at timer are set to OFF.
- Place DIP switches 3 and 8 to ON as shown in A, Abb. 66.
In this preliminary configuration, the condensate drain in
terval can be adjusted in seconds. (See also Bürkert in
structions in the annex).
- Switch on power.
- Adjust switch-on time with potentiometer t
on
assigned to
DIP switches 1 to 3 (preliminary 15 seconds). Turn poten
tiometer fully ccw. The desired switch-on time of 15 sec
onds wihtin the range setting of 1.5 to 30 seconds is ap
prox. between 5 and 7 o'clock (Abb. 67). The exact posi
tion has to be found with a stop watch.
- Then adjust drain time with potentiometer t
off
assigned
to DIP switches 6 to 8 (6 seconds). Turn potentiometer
fully ccw, then start turning cw. The desired switch-on
time of 6 seconds within the range setting of 1.5 to 30
seconds is approx. between 2 and 4 o'clock (Abb. 67).
The exact position has to be found with the stop watch.
- Finally place DIP switches 3 to OFF and 1 to ON as shown
in B, Abb. 66. In this configuration the preliminary con
densate drain interval is converted in a range setting of
1.5 to 30 min. The setting of time is proportional: setting
15 sec in the time range 1.5...30 sec (preliminary setting)
becomes 15 min when changing the range to 1.5...30
min (final setting). The operating time will now be 15 min
utes.