Instruction Manual Breathing Air Compressors
41
Abb. 53 Combined plate valve
Pressure side
Intake side
Top view
VALVE CHANGE
Changing the valves should be performed by trained person
nel, only.
Valve change is described in the workshop manual which is
available through the BAUER technical service.
4.5.9. CONDENSATE DRAIN
DESCRIPTION
The intermediate separators and the oil and water separator
or filter system are fitted with manual drain taps. The con
densate should be drained every 15 minutes during oper
ation by slowly opening the taps one after the other.
Abb. 54 Condensate drain taps, intermediate separa
tors
1
1 Manual drain tap
1
Abb. 55 Condensate drain tap, filter system P31
1 Manual drain tap
1
4.5.10. AUTOMATIC CONDENSATE DRAIN (OPTION)
DESCRIPTION
The automatic condensate drain unit drains the intermediate
separators and the oil and water separator after the last