Instruction Manual Breathing Air Compressors
49
RemedyCauseTrouble
Automatic Condensate Drain (optional)
Drain valves do not close No control air Check control air line
Drain valves leaking Dismantle drain valve and clean
Drain valves do not open Condensate drain valve piston jammed Dismantle drain valve, clean or replace
valve
Solenoid valve does not close Solenoid valve faulty Check solenoid valve and replace if ne
cessary
No electrical signal Check for voltage from timer
Solenoid valve does not open Solenoid valve faulty Check solenoid valve and replace if ne
cessary
Continuous electrical signal Check electrical control circuit and ti
mer
Unsatisfactory drainage (lot of conden
sate from manual valves)
Nozzle in 3rd stage drain valve clogged Remove nozzle, clean
Note: 3rd stage 0,8 mm ∅