EasyManua.ls Logo

Bauer VARIUS - Determination of F.A.D; Determination du Debit

Bauer VARIUS
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Determination of F.A.D
The F.A.D is measured by filling a bottle of min.
5 ltrs. or max. 1
O ltrs. (water volume).
Prescribed filling pressure :
200 bar/2860 psig.
Instructions:
Open bottle valve, to ensure
that the bottle is empty.
Connect bottle to the closed
filling valve.
Start compressor and when it
has reached 200 bar/2860 psig
open filling valve.
Note the exact filling time taken to reach
filling pressure.
(convert seconds to decimal minutes).
Calculation of F.A.D
Cylinder volume (ltrs) x filling pressure (bar)
filling time (min)
Cylinder volume
(f3)
x filling pressure (bar)
filling time (min)
6
F.A.D. (ltrs/min)
F.A.D.
(cf
m)
Determination du debit
On determine le debit
en
remplissant une bouteille
d'une capacite minimale de 5 litres ou maximale de
10
litres.
Pression de remplissage prescrite:
200 bar
Instructions:
Ouvrir le robinet de la bouteille
afin de la vider.
Brancher la bouteille au robinet
de remplissage ferme.
Mettre en marche le compresseur et ouvrir le
robinet de remplissage des que la pression a
atteint 200 bar.
Chronometrer le temps exact de remplissage et
calculer le debit selon
la
formule ci-dessous
{convertir les secondes en minutes decimales).
Calcul du debit
Cap. de la bout
(I)
x Press. de rempl. (bar)
Temps de remplissage (min)
Debit (I/min)

Related product manuals