Determination of F.A.D
The F.A.D is measured by filling a bottle of min.
5 ltrs. or max. 1
O ltrs. (water volume).
Prescribed filling pressure :
200 bar/2860 psig.
Instructions:
• Open bottle valve, to ensure
that the bottle is empty.
• Connect bottle to the closed
filling valve.
• Start compressor and when it
has reached 200 bar/2860 psig
open filling valve.
• Note the exact filling time taken to reach
filling pressure.
(convert seconds to decimal minutes).
Calculation of F.A.D
Cylinder volume (ltrs) x filling pressure (bar)
filling time (min)
Cylinder volume
(f3)
x filling pressure (bar)
filling time (min)
6
F.A.D. (ltrs/min)
F.A.D.
(cf
m)
Determination du debit
On determine le debit
en
remplissant une bouteille
d'une capacite minimale de 5 litres ou maximale de
10
litres.
Pression de remplissage prescrite:
200 bar
Instructions:
• Ouvrir le robinet de la bouteille
afin de la vider.
• Brancher la bouteille au robinet
de remplissage ferme.
• Mettre en marche le compresseur et ouvrir le
robinet de remplissage des que la pression a
atteint 200 bar.
• Chronometrer le temps exact de remplissage et
calculer le debit selon
la
formule ci-dessous
{convertir les secondes en minutes decimales).
Calcul du debit
Cap. de la bout
(I)
x Press. de rempl. (bar)
Temps de remplissage (min)
Debit (I/min)