BA series pumps
1401 Pump unit with diesel drive
8.23
In addition, if
automatic engine
shutdown is installed.
Stop signal from monitoring element
because of:
- oil pressure too low.
Check engine oil level.
- cylinder head temperature too high. Cooling air passages blocked
or cooling system otherwise
affected.
- alternator has failed. See workshop manual.
Malfunction Possible causes Remedial action
Low engine power,
output and speed.
Fuel supply is obstructed:
- Tank run dry.
Add fuel.
- Fuel filter blocked. Renew fuel filter.
- Tank venting is inadequate. Ensure that tank is adequately
vented.
- Leaks at pipe unions. Check threaded pipe unions
for leaks.
- Air in the fuel system. Check fuel system for
penetration of air. Check air
vent valve.
- Speed control lever does not remain
in selected position.
Prevent speed control from
moving.
Malfunction Possible causes Remedial action
Low engine power,
output and speed,
black exhaust smoke.
Air cleaner blocked. Remove dirt from air cleaner.
Incorrect valve clearances. Adjust valve clearances.
Malfunction at injector. See workshop manual.
Malfunction Possible causes Remedial action