Operation
EL6900 29Version: 2.2.0
Manufacturer Type Comment
Beckhoff AX5801 TwinSAFE Drive option card: safe restart lock
Beckhoff AX2000 AS option safe restart lock
Siemens SIRIUS series S00
3RT1016-1BB42
Contactor
Telemecanique LP1K09 Contactor
The tests were carried out as function tests only. The information provided in the respective manufacturer
documentation remains valid.
Note
Recommended protective circuits
We recommend R/C or diode-based protective circuits for these devices.
Varistor-based protective circuits should not be used.
4.3 Operation in potentially explosive atmospheres (ATEX)
4.3.1 Special conditions
WARNING
Observe the special conditions for the intended use of Beckhoff fieldbus
components in potentially explosive areas (directive 94/9/EU)!
The certified components are to be installed in a suitable housing that guarantees a protec-
tion class of at least IP54 in accordance with EN 60529! The environmental conditions dur-
ing use are thereby to be taken into account!
If the temperatures during rated operation are higher than 70 °C at the feed-in points of ca-
bles, lines or pipes, or higher than 80°C at the wire branching points, then cables must be
selected whose temperature data correspond to the actual measured temperature values!
Observe the permissible ambient temperature range of 0 to 55 °C when using Beckhoff
fieldbus components in potentially explosive atmospheres!
Measures must be taken to protect against the rated operating voltage being exceeded by
more than 40% due to short-term interference voltages!
The individual terminals may only be unplugged or removed from the Bus Terminal system
if the supply voltage has been switched off or if a non-explosive atmosphere is ensured!
The connections of the certified components may only be connected or disconnected if the
supply voltage has been switched off or if a non-explosive atmosphere is ensured!
The fuses of the EL92xx power feed terminals may only be exchanged if the supply voltage
has been switched off or if a non-explosive atmosphere is ensured!
Address selectors and ID switches may only be adjusted if the supply voltage has been
switched off or if a non-explosive atmosphere is ensured!
The fundamental health and safety requirements are fulfilled by compliance with the following standards:
EN 60079-0: 2006
EN 60079-15: 2005