Function blocks
Function blocks for TwinSAFE logic components 193
Value
Name
Description
39
0x27
MOVE-UP-TDC2
(Pendulum mode)
The function block assumes the MOVE-UP-TDC2 state if
TDC2Area or TDC2ExceededArea becomes TRUE in MOVE-
DOWN-CONTRA-CLOCKWISE or MOVE-UP-CONTRA-
CLOCKWISE state.
40
0x28
MOVE-STOP-TDC2
(Pendulum mode)
The function block assumes the MOVE-STOP-TDC2 state if
the press is stopped in MOVE-UP-TDC2 state.
41
0x29
MOVE-START-TDC2
(Pendulum mode)
The function block assumes the MOVE-START-TDC2 state if
the Reset input becomes TRUE in MOVE-STOP-TDC2 state.
Table 3-162: Internal identifier of the FB
Type
Description
FB CamMonitor
This description applies to BLG 1.0 / BLG 2.0 (internal version number)