12. Shutdown
Interrupt the hydraulic oil supply.
Relieve the device from pressure!
Remove all pipes and hoses from the device and loosen all fastenings for disassembly!
13. Disposal
Observe the disposal instructions of the lubricant manufacturer when lubricant is changed! Lubricants
or cloths contaminated with lubricant, etc. must be collected in specially marked reservoirs and
disposed of accordingly.
The device and the cartridges must be disposed of properly and professionally and according to the
national and international laws and regulations.
14. Troubleshooting
Malfunction Possible cause Possible remedy
Device does not
supply lubricant;
eccentric shaft does
not rotate
No hydraulic oil pressure available at
connection
Check hydraulic connection for pressure
Input filter and adjusting throttle dirty Clean filter and adjusting throttle or exchange them
Adjusting throttle closed
Turn adjusting throttle approx. 1 ½ revolutions counter
clockwise and switch off oil supply. Switch adjusting throttle
on again after functional test.
Hydro motor defective Exchange hydro motor
Counter-pressure in return too high
max. 30 bar
Check hydraulic system
Device delivers no
lubricant; however,
eccentric shaft rotates
Air bubble in the cartridge
Unscrew cartridge from adapter. Apply pressure by hand on
the follow-up piston in the cartridge until bubble-free grease
leaks at the cartridge opening. Screw cartridge in again.
Cartridge empty Renew cartridge
Seal/s in cartridge adapter damaged or
missing
Exchange or install seals
Pump element defective or worn Exchange pump element
Dirt or air in suction area Clean pump element and suction area
Lubricant leakage at
the bore of the
pressure limiting
valve
System counter-pressure too high Check lubrication system
Pressure limiting valve defective Exchange pressure limiting valve
Lubricant quantity too
small or too big
Oil flow incorrectly set Set flow rate with adjusting throttle
Oil leakage at the
lateral relief bore
Shaft sealing ring on hydro motor
defective
Exchange hydro motor