Do you have a question about the Bemer Therapy System Evo and is the answer not in the manual?
Instructions for use are integral to the BEMER Therapy System Evo for safe and efficient operation.
Your BEMER Therapy System Evo may differ from illustrations; descriptions apply analogously.
Mentions of product/company names may be registered trademarks of respective companies.
Masculine nouns used for readability apply equally to all genders.
Definitions of hazard level symbols: Danger (severe injury/death), Warning (severe injury/death), Caution (minor injury), Note (product/data loss).
Explanation of safety symbols: Warning sign (risk), Command sign (action), Prohibition sign (prohibited action), Information (tips).
Information on liability for damages and copyright protection of the manual's content.
Details warranty conditions; statutory rights remain unaffected.
Serious incidents must be reported to the manufacturer and competent authorities.
Product must only be used for described purposes; any other use is improper.
B.Box Evo generates signals for PEMF/LLLT; applicators stimulate microcirculation and alleviate conditions.
B.Box Evo acts as an interface for LLLT and PEMF applications.
Indications are defined by applicators; PEMF is adjuvant therapy for wound healing, musculoskeletal, and polyneuropathy issues.
PEMF contraindicated for active implants; LLLT contraindicated near eyes/mucous membranes.
PEMF may affect pulse/blood pressure; LLLT may cause skin reactions like redness or itching.
Applicators are used for systemic or targeted treatment with the B.Box Evo.
For end users aged 14+ and medically trained personnel.
For people aged 14+, children under 14 require supervision.
Body regions treated depend on the applicator; whole-body or specific areas.
For home or clinical settings, used by laypersons or trained personnel.
Improves microcirculation and tissue supply; LLLT improves skin appearance.
Active implants may be disrupted by PEMF; avoid use.
Loose cables pose a tripping/strangulation hazard; lay flat and use fastening aids.
Damaged batteries pose fire/explosion risk; dispose of properly.
Failure to follow instructions can lead to operating errors and life-threatening hazards.
Contact with exposed or unapproved cables can cause electric shock.
Water and electricity combination can cause electric shock; do not use in humid environments.
Incorrect voltage can cause electric shock and device damage; check local voltage.
Shared use of modules can transmit diseases; clean applicators between uses.
Unattended overheated equipment poses fire/burn risk; do not leave unattended.
Contaminated modules on injured skin transmit diseases; do not apply to injured skin.
Light therapy near eyes risks retinal injury; wear safety glasses.
Light therapy with certain ointments/medications may cause toxic reactions; avoid combination.
Simultaneous contact with metallic parts can cause burns from leakage currents.
Water ingress causes short circuits and danger; disconnect power before cleaning.
Magnetic attraction can cause pinching/bruising; avoid reaching between components.
User errors can cause elevated vital signs; ensure proper introduction and training.
Materials may cause skin reactions; discontinue use and consult a doctor if reactions occur.
LLLT modules can reach 44°C at >35°C ambient temp; allow cooling between treatments.
RF devices may be affected by electromagnetic forces; maintain distance.
Unsuitable environments can cause malfunctions; use in dry rooms only.
Magnets can disrupt storage media; keep media away from magnets.
Unauthorized repairs can cause material damage; only authorized personnel should perform work.
Consult doctor for atypical reactions; lists conditions requiring physician approval for PEMF.
Consult doctor for atypical reactions; lists conditions requiring physician approval for LLLT.
Professionals must ensure employee awareness of safety, training, and supervision.
Lists symbols and their meanings/locations on the device and packaging.
Recommends wearing safety glasses during light therapy to protect eyes.
Risk to health/environment from toxic materials; do not dispose of as household waste.
Details temperature, humidity, and pressure ranges for operation and storage.
Provides technical specifications for the B.Box Evo, such as dimensions, weight, and power.
Lists technical specifications for B.Body, B.Bed, B.Pad, B.Spot, B.Sit, and B.Grip Evo applicators.
Lists technical specifications for B.Light Clear/Restore Evo and B.Box Evo Battery Stand.
Lists technical specifications for accessories like power supplies, adapters, and mounts.
Details RF emissions and conformity with standards like CISPR 11.
Details immunity tests and compliance levels for various electromagnetic disturbances.
Further details on electromagnetic immunity tests and compliance levels.
Provides guidelines for maintaining safe distances from RF telecommunication devices.
Describes the system's purpose (PEMF and LLLT) and its components.
Illustrates the B.Box Evo controller and its associated accessories.
Shows the different applicator types for PEMF and LLLT therapies.
Displays various accessories available for the system.
Details the contents of different BEMER sets and individual product availability.
Lists products available for purchase individually, categorized by application and accessories.
Identifies and explains the key components of the BEMER Therapy System Evo.
Describes the B.Body Evo applicator for full-body therapy.
Describes the B.Bed Evo applicator for full-body therapy in bed.
Describes the B.Pad Evo applicator for targeted treatment of small body areas.
Describes the B.Spot Evo applicator for focused, targeted treatment.
Describes the B.Sit Evo applicator for targeted treatment of seated patients.
Describes the B.Light Clear Evo and B.Light Restore Evo for light therapy.
Describes the B.Grip Evo adapter for connecting application modules.
Details the B.Box Evo Battery Stand for mains-independent operation.
Describes the B.Grip Evo Attachment Strap for securing modules to body parts.
Details the B.Box Evo Power Supply for domestic power connection.
Details the B.Box Evo Car Adapter for vehicle power connection.
Recommends wearing safety glasses during light therapy.
Describes the B.Box Evo Wall Mount for secure wall attachment.
Warns about risks of damage from incorrect transport or storage.
Refers to chapter 12 for meaning of packaging symbols.
Recommends keeping original packaging for storage and returns.
Guidelines for using PEMF applicators for full-body and targeted treatments.
Explains the 'plus Signal' feature for enhanced cell excitation.
Details daytime and nighttime full-body therapy using B.Body/B.Bed Evo.
Outlines the basic plan for full-body therapy cycles and intensity levels.
Instructions for setting and activating the sleep program.
Describes how to apply targeted treatments and user-defined programs.
Provides guidance on using LLLT applicators for skin treatment.
Details the use of B.Light Clear Evo for skin conditions and cosmetic purposes.
Details the use of B.Light Restore Evo for muscle/joint pain relief and wrinkle reduction.
Instructions for connecting the B.Box Evo to its various stands and mounts.
Instructions for connecting the power supply or car adapter to the B.Box Evo.
How to connect applicators and modules to the B.Box Evo controller.
Steps to turn on the B.Box Evo and initial settings.
Instructions for powering on the device and accessing the start screen.
Overview of the main menu options for selecting therapies.
Explains the symbols and information displayed on the status bar.
Guide to configuring basic settings before starting an application.
How to adjust volume and enable voiceover for accessibility.
Instructions to adjust display brightness and auto-brightness settings.
Steps to set the current time on the device.
How to create custom therapy programs in expert mode.
Accessing system settings like ambient lighting, energy saving, and language.
How to find system version, software, firmware, and operating time.
Overview of the main menu options and connectable application modules.
How to select intensity levels for therapy and start/stop treatment.
How to select therapy programs, intensity, and duration.
Instructions for setting and activating the sleep program.
How to select light intensity levels and start light therapy.
Warning about risk of infection from shared use of modules.
Guidelines for cleaning the device and applicators using approved agents.
Instructions for disinfecting applicator surfaces for professional users.
Guidance on proper disposal of the device and battery, avoiding household waste.
Lists common error codes, their causes, and troubleshooting steps.
Explains various symbols found on the device and its packaging.
| Category | Personal Care Products |
|---|---|
| Model | Bemer Therapy System Evo |
| Technology | PEMF (Pulsed Electromagnetic Field) |
| Programs | Pre-set and customizable programs |
| Intensity Levels | Adjustable intensity levels |
| Power Supply | AC/DC adapter |
| Manufacturer | Bemer Group AG |