Technical data IRDH275(B)
75
IRDH275_D00122_02_M_XXEN/10.2016
Switching components
Switching components.............................................2 changeover contacts: K1 (Alarm 1), K2 (Alarm 2, device fault)
Operating principle K1, K2 (Alarm 1, Alarm 2).............................................................................N/O or N/C operation
Factory setting (Alarm 1/Alarm 2)........................................................................................................... N/O operation
Electrical endurance...........................................................................................................12 000 switching operations
Contact class ...................................................................................................................................... IIB (IEC 60255-23)
Rated contact voltage..................................................................................................................... AC 250 V / DC 300 V
Making capacity...............................................................................................................................................AC/DC 5 A
Breaking capacity............................................................................................................... 2 A, AC 230 V, cos phi = 0.4
.......................................................................................................................................... 0,2 A, DC 220 V, L/R = 0.04 s
Minimum contact current at DC 24 V .....................................................................................................2 mA (50 mW)
General data
EMC ................................................................................................................. acc. to IEC 61326-2-4:2006-06 Ed. 1.0
Shock resistance IEC 60068-2-27 (device in operation)...........................................................................15 g / 11 ms
Bumping IEC 60068-2-29 (during transport) .............................................................................................40 g / 6 ms
Vibration resistance IEC 60068-2-6 (device in operation)................................................................1 g / 10…150 Hz
Vibration resistance IEC 60068-2-6 (during transport) ....................................................................2 g / 10…150 Hz
Ambient temperature (during operation)..........................................................................................-10 °C…+55 °C
Storage temperature range.................................................................................................................-40 °C…+70 °C
Climatic class acc. to IEC 60721-3-3......................................................................................................................... 3K5
Operating mode............................................................................................................................ continuous operation
Mounting ............................................................................................................................. as indicated on the display
Distance to adjacent devices ............................................................................................................................≥ 30 mm
Connection............................................................................................................................................. screw terminals
Connection, rigid, flexible........................................................................................... 0.2…4 mm
2
/ 0.2…2.5 mm
2
Connection, flexible with connector sleeve, without/with plastic sleeve........................................ 0.25…2.5 mm
2
Conductor sizes (AWG).......................................................................................................................................... 24-12
Tightening torque ............................................................................................................................................... 0.5 Nm
Protection class, internal components (DIN EN 60529).......................................................................................... IP30
Protection class, terminals (DIN EN 60529)............................................................................................................. IP20
Type of enclosure..................................................................................................................... X112, free from halogen
DIN rail mounting............................................................................................................................................ IEC 60715
Flammability class........................................................................................................................................... UL94 V-0
Software version IRDH275 ............................................................................................................................. D160 V1.8

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bender ISOMETER IRDH275 and is the answer not in the manual?

Bender ISOMETER IRDH275 Specifications

General IconGeneral
BrandBender
ModelISOMETER IRDH275
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals