10
Bentone B 30/B 40 J/K
1.5 Recommended nozzle and pressure
Nozzle: 45° Solid/semisolid
60° Solid/semisolid
80° Solid/semisolid
Pump pressure 10 bar (8-15 bar)
Because of the various boiler types with varying furnace geometries and
furnace loads, it is impossible to commit to a certain scattering angle or a
specific distribution pattern.
It should be noted that the scattering angle and distribution pattern changes
with pump pressure.
1.6 Setting of ignition electrodes and brake plate
a b c d
B30 2,5-3,5 7,0-9,0 1,0-2,0 4,5-5,0
B40 2,5-3,5 7,0-9,0 1,0-2,0 4,5-5,0
1.6.1 Electric Specification
Burner correspond to IP 40
Type Motor Complete
burner
Sound
B 30
180 W
1,3 A 50 Hz
360 W
230 V 50 Hz
1,6 A
84 dBA ± 0,5
dBA
B 40
250 W
1,7 A 50 Hz
480 W
230 V 50 Hz
2,6 A
87 dBA ± 0,5
dBA
a
b
c
d
!
*NB It is important that
the spark does not strike
against the brake plate or
nozzle