MNS-BB Software User Guide
-102-
alarm <enable/disable>: This command globally enables or disables the alarm action.
Syntax: alarm <enable|disable>
LE2425A(alarm)## alarm enable
Alarm system Enabled
period time: This command sets the duration of relay action for the momentary type signal.
Syntax: period time=<1..10>
LE2425A(alarm)## period time=5
Relay closure Time Set
Show alarm: It displays the current status of Alarm system.
Syntax: show alarm
LE2425A(alarm)##show alarm
Alarm Events Configuration
------------------------------------
Alarm Status: DISABLED
Relay Closure Time Period: 3 Seconds
Id Description Mode
1 Cold Start NOT ENABLED
2 Warm Start NOT ENABLED
3 Link Up NOT ENABLED
4 Link Down NOT ENABLED
5 Authentication Failure NOT ENABLED
6 RMON Raising Alarm NOT ENABLED
7 RMON Falling Alarm NOT ENABLED
8 Intruder Alarm NOT ENABLED
9 Link Loss Learn Triggered NOT ENABLED
10 Broadcast Storm Detected NOT ENABLED
11 STP/RSTP Reconfigured NOT ENABLED
If you enable the Alarm system and add event Ids then the status will be change to SUSTAINED or
MOMENTARY (It depends on the event).
LE2425A(alarm)##show alarm
Alarm Events Configuration
------------------------------------
Alarm Status: ENABLED
Relay Closure Time Period: 3 Seconds
Id Description Mode
1 Cold Start
MOMENTARY
2 Warm Start NOT ENABLED
3 Link Up NOT ENABLED
4 Link Down NOT ENABLED
5 Authentication Failure NOT ENABLED
6 RMON Raising Alarm NOT ENABLED
7 RMON Falling Alarm NOT ENABLED
8 Intruder Alarm NOT ENABLED
9 Link Loss Learn Triggered NOT ENABLED
10 Broadcast Storm Detected NOT ENABLED
11 STP/RSTP Reconfigured NOT ENABLED
19.2 Web: View and Configure Alarms
In the web browser interface:
1. Click on the [Configuration].
2. Click on [Alarms].
3. [Enable|Disable] the Alarm event from the predefined list.
4. Click [Save] to save the configuration.